Missed out on this deal?
Unsubscribe anytime.
|
APS DISPOSAL LIST |
||
|
MADE |
MODEL |
SERIAL |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8160 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8162 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8260 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8161 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8261 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8165 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8166 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8168 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8170 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8164 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8355 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8158 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8156 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8163 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8169 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U9720 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8167 |
|
APS-TRANSTECHNIK |
U750DC/460AC3-120AC2-28DC/P66-5-12/F60 |
U8356 |
Siemens Transportation Systems
Type U 750DC/460AC3-120AC2-28DC/P66-5-12/F60
Auxiliary Power Supply
For S70 Houston
Running Maintenance
And Servicing Manual
transtechnik
Date: October 7, 2005
Author: John Freund
Document #: A-1-1355-32800, Rev.: 1
K003-RMSM_R20_070ct05.doc
....
Houston S?O Running Maintenance and Service Manual
09.1.4.3 TECHNICAL DATA
TABLE 1-1: CHARACTERISTICS OF THE UNIT
|
INPUT CHARACTERISTICS |
SYMBOL |
VALUE |
|
Nominal input voltage |
VIN |
750 Vdc |
|
Input voltage range |
|
420 ... 1,040 Vdc |
|
Min. operation voltage (with nominal output characteristics) |
VImin |
420 Vdc |
|
Max. operation voltage (with nominal output characteristics) |
VImax |
1,040 Vdc |
|
Trigger voltage active input voltage limiter |
Vlim |
150 v (130 ... 170) v |
|
Discharge time input capacitor |
tdi |
< 180 s (VI = 1,040 V) |
|
INTERMEDIATE CIRCUIT |
SYMBOL |
VALUE |
|
Nominal intermediate circuit voltage |
VZN |
690 v ± 10 v |
|
Measurement by voltage transducer Type LV100SP4, ratio 1000:500, RV = 100 + 1.9 kOhms |
|
33.9 rnA |
|
Min. intermediate circuit voltage |
VZmin |
640 v |
|
Max. intermediate circuit voltage |
VZmax |
750 v |
|
Nominal intermediate circuit current |
IZN |
100 A± 10% |
|
Discharge time intermediate circuit capacitors |
tdz |
< 180 s (VZ = 690 V) |
|
OUTPUT AC1 |
SYMBOL |
VALUE |
|
Output wave shape |
|
sinusoidal (PWM) |
|
3-Phase output voltage (phase to phase) |
VAC |
3 x460 VRMS ± 5% |
|
Frequency |
f |
60 Hz± 1% |
|
Output power (continuous) cos D |
PN |
66 kVA 0.85 |
|
Output power for motor inrush (5 s) cos D |
p |
144 kVA 0.4 |
|
THD |
|
< 8% |
|
Clock frequency |
f |
4,500 Hz |
|
Overall efficiency at VIN and full load |
|
> 90% |
K003-RMSM_R10_070ct05.doc G TRANSTEC::HNIK Page 6 of 89
|
.- ·-
Houston 870 Running Maintenance and Service Manual
|
OUTPUT AC2 |
SYMBOL |
VALUE |
|
Output wave shape |
|
sinusoidal (PWM) |
|
Output voltage normal operation backup mode |
VAC VAC |
2 x 120 VRMS ± 5 % 3 x 460 VRMS ± 5 % |
|
Frequency |
f |
60 Hz± 1% |
|
Output power (continuous) cos I;J normal operation cos I;J backup mode |
PN |
5 kVA 1 0.8 |
|
Output power for motor inrush (5 s)
cos D |
p |
120 V: 6 kVA 460 V: 20 kVA 0.3 |
|
THD |
|
< 10% |
|
Clock frequency |
f |
4,500 Hz |
|
Overall efficiency at VIN and full load |
|
> 90% |
|
LVPS AND BATTERY CHARGING |
SYMBOL |
VALUE |
|
Nominal input voltage of DC/DC module |
VIN |
750 Vdc |
|
Input voltage range |
|
420 ... 1,040 Vdc |
|
Min. operation voltage (with nominal output characteristics) |
VImin |
420 Vdc |
|
Max. operation voltage (with nominal output characteristics) |
VImax |
1,040 Vdc |
|
Nominal output power |
PDC |
12 kW |
|
Nominal output voltage |
VN |
24 Vdc D 1.5 % |
|
Max. charge current (adjustable) |
v |
25.6 ... 31.4 v |
|
Max. charge current (factory setting) |
v |
29.4 v |
|
Tolerance |
|
±1.5% |
|
Battery undervoltage |
v |
16.8 v |
|
Battery overvoltage |
v |
34 v |
|
TEMPERATURE CONTROLLED BATTERY CHARGING |
SYMBOL |
VALUE |
|
|
Battery voltage at 20 oc |
VT1 |
29.4 v |
|
|
Battery voltage at 60 oc |
VT2 |
27.0 v |
|
|
Gradient voltage vs. temperature |
!'J..V |
-o.o6 vrc |
|
|
Max. output current (total) Tolerance Range of tolerance Measurement by current transformer Type: T60404 X053; ratio: 500 A: 250 mA |
IG
IS |
420 A ±5 % 399 ... 441 A 210 mA |
|
K003-RMSM_R10_070ct05.doc @ TRANSTECHNIK Page 7 of 89
...-_ ,
Houston S70 Running Maintenance and Service Manual
|
TEMPERATURE CONTROLLED BATIERY CHARGING (CONTINED.) |
SYMBOL |
VALUE |
|
Max. charging current Tolerance Range of tolerance Measurement by current transformer Type: T60404 X051 ; ratio: 200 A : 100 rnA |
IL
IS |
50 A ±5% 47.5 ... 52.5 A 25 rnA |
|
I > X (load monitoring) Range of tolerance Measurement by_ current transformer |
I >X
IS |
5A 4.75 ... 5.25 A 2,5 rnA |
|
Output power |
p |
12 kW |
|
Load characteristic |
|
IN curve |
|
Ripple |
VRipple |
::; 500 mV RMS |
|
Clock frequency of chopper |
ftakt |
20.000 Hz |
|
DIAGNOSTICS AND EXTERNAL INTERFACES |
|
|
Status and fault indication |
Recording of fault conditions Storage of all operation parameters with date and time in non-volatile memory Display via RS232 on diagnostic notebook Diagnostics down to module level |
|
Interfaces |
RS 232 (fault diagnostics via notebook) 5 Floating relay contacts (for resistive loads only) MVB |
|
ENVIRONMENTAL CONDITIONS |
|
|
Temperature range (in operation) |
- 25 oc ... + 45 oc -13F ... 113F |
|
Humidity |
0% ... 100% |
|
Shock and vibration x: y: z: |
5g 2g 3g |
|
ADDITIONAL EQUIPMENT |
|
|
Dead Battery Start |
|
|
High Voltage Relay |
|
,.... · · ;• ;· .... ""!. ,..... : .· ..... ..,_
Houston S70 Running Maintenance and Service Manual
|
MECHANICAL CONSTRUCTION |
|
|
Housing |
Aluminum |
|
Dimensions (L x W x H) |
1,850 mm x 1,100 mm x 485 mm 72.835 x 43.307 x 19,095 inch |
|
International protection level |
IP 54 (electronics compartment) IP 22 (air duct) |
|
Cooling |
forced cooling |
|
Mounting |
Roof mounted |
|
Weight |
440 kg I 970 lbs |
|
RELATED STANDARDS |
|
|
EN 50155 (IEC 571, VDE0115-200) 05/96 |
Railway applications, Electronic equipment used on rolling stock |
|
IEC 61287-1 (07/95) |
Power converters installed on board rolling stock; characteristics and test methods |
|
EN 50125-1 |
|
|
IEC 61373 |
|
No questions yet. Be the first to ask the seller.